Knoll Systems Universal Remote VC224PM User Manual

VC201 Keypad functions  
Volume level  
indicator for  
this room only  
Room power on and  
volume up button  
Mute button (volume  
level led blinks)  
systems  
Infrared signal  
receiver  
(VC201ionly)  
Room power on,  
volume down and  
all room power off  
button (hold down  
button for three led  
blinks)  
VC224pm  
VC226pm  
System status led and  
infrared signal confirming  
led (VC201i only)  
Limited Warranty  
Digital Four or Six Room  
Knöll Systems warrants VC224pm and VC226pm systems sold in the USA or Canada  
by authorized Knöll dealers to be free from defects in materials and workmanship.  
This warranty extends for three full years from the date of purchase by the  
consumer. Any products returned freight prepaid to Knöll Systems and found to be  
defective by Knöll Systems within the warranty period will be repaired or replaced  
at Knöll Systems option, at no charge. Knöll Systems will not be responsible for the  
actual cost of installation or removal of the product, nor for any consequential or  
incidental damages. Some states do not allow the exclusion or limitation of  
incidental or consequential damages, so the above limitation or exclusion may not  
apply to you. This warranty gives you specific legal rights. You may have additional  
rights which vary from state to state. Knöll products sold outside of the USA and  
Canada may be covered by warranties provided by an authorized Knöll distributor.  
Stereo Volume Control System  
INSTALLATION  
AND OPERATION  
MANUAL  
Please contact the distributor in the country that the Knöll product was purchased.  
* DMS, Powermatch, Transformer free and Digicom  
are trademarks of Knöll Systems  
Printed in Canada  
Knöll Systems, Richmond, BC & Point Roberts WA  
C COPYRIGHT 1998-2003, Knöll Systems, All Rights Reserved  
Knöll Systems  
tel (604) 272-4555  
fax (604) 272-5595  
In America:  
In Canada:  
145 Tyee Drive  
11791 Machrina Way #120  
Point Roberts, WA 98281 Richmond, B.C. V7A 4V3  
Version 1.4  
 
Installation  
Cat wires from rooms with more than one VC201 are run from one VC201 to  
the other then home run back to the controller.  
Installing the digital volume control system should be relatively  
easy. With a bit of planning, it will give trouble free service  
for years.  
It is very important to use a top quality RJ45 8/8  
crimper tool. We strongly suggest using a cat 5  
RJ45 electronic tester to verify the wire conductors.  
Basic System Layout and Pre-Wiring: See “Typical Wiring Diagram” on  
the centerfold page. The VC224pm and VC226pm make a noticeable “click”  
sound when changing volumes. We suggest mounting it in a low voltage panel,  
electrical room, closet, etc. We do not suggest connecting more than one  
VC224pm or VC226pm to a single amplifier or receiver, even if it is a high  
power model because a variety of power sharing problems can occur.  
One or two VC201 keypads can work on a single room or zone but only one  
VC201i can be connected to a single VC224pm or VC226pm room or zone.  
The VC200 keypad does not work with this system.  
Connection to Stereo Equipment:Remove the VC224pm orVC226pm green  
four-position speaker connector labelled "INPUT". The stereo amplifier or  
receiver outputs (left and right) are connected to this VC224pm or VC226pm  
connector. Be very careful to observe the correct polarity. This controller  
uses independent floating grounds so bridged amplifiers can be used safely.  
VC224pm and VC226pm controllers are rated for  
use with maximum 120 watt per channel amplifiers.  
DO NOT use higher-powered amplifiers with this  
product for safety reasons.  
Use the standard T568A wiring practices to run a cat 5 or cat 3 wire from  
the keypad or controller to the VC224pm or Vc226pm. If more than one  
keypad controls a single VC224pm or Vc226pm room, daisy chain the cat  
wire from keypad to keypad. If the VC226pmi is notlocated next to the  
stereo, run a single eight-conductor cat 3 or cat 5 wire run and four  
speaker wire conductors from the stereo to the controller for the power  
supply, the infrared system, future upgrades such as paging override and of  
course the steeo speaker sound.  
The amplifier or receiver must be rated for four ohm speaker use to work  
properly with the VC224pm or VC226pm controller. Connect the controller  
to the amp or receivers speaker A or speaker B terminals. Wire the VC224pm  
or VC226pm connectors labelled “ROOM1", "ROOM2" etc. directly to the  
correct room speakers, again strictly observing polarity.  
From each speaker run a home run fire ratedtwo-conductor speaker wire  
to the VC224pm or VC226pm. To save time and money, most installers run a  
four-conductor speaker wire from the VC224pm or VC226pm to the closest  
appropriate speaker and then run a short two-conductor speaker wire to  
the other speaker. If there is more than one pair of speakers connected to  
a single VC224pm or VC226pm zone, the speakers can be wired in series or  
parallel whichever makes the impedance closest to 4 or 8 ohms. Do not  
attemptto make the final combined speaker impedance less than 4 ohms.  
Power Requirements: The VC224pm and VC226pm are shipped with a 12VDC  
500mA (or more) power supply (supplies power to the keypads). If possible,  
connect the 12vdc power supply to the switched outlet on the rear of the  
amplifier or receiver. This wiring causes the VC224pm or VC226pm  
controller to reset to its selectable “boot up” every time the receiver or  
amplifier is turned on but when the power is off the IR section of the  
VC201i will not work. If the IR is required to work all the time, then the  
controller power supply must connected to an unswitched outlet.  
Connecting VC201/VC201i keypads to VC224pm and VC226pm controllers:  
Use a single cat5 wire using all eight conductors (usually run inside a wall).  
Always use standard T568A Cat 5 wiring practices (shown below). Use the  
correct wire pairs. Polarity is VERY important! The stereo signal is not  
routed to the keypad, just the digital control signals. Signals from an  
infrared receiver (if used) are routed down the same Cat 5 wire. If more  
than one keypad (VC201, not VC201i) is to be connected to a VC224pm or  
VC226pm controller, the wires to the keypads are paralleled. continued..  
Installer Selectable “BOOT UP”: The VC224pm and VC226pm allow the  
installer to select how the volume control “boots up” in each room when the  
controller first receives 12vdc power. For this feature to work, be sure to  
plug the 12vdc power supply to the switched AC outlet on the rear of the  
receiver or amplifier. Please note #6/12 and S/Mute labels are inverted  
on zones 2, 4 and 6 on the version 1.3 board.  
To always Start MUTEed make sure the shunt on the right side of the  
controller room number labelled “S/MUTE” is in place. Remove this shunt and  
this room starts with the music on.  
brown 8  
white/brown 7  
orange 6  
white/blue 5  
blue 4  
To always start up in a quiet position #6 (of 17) sure the shunt on the right  
side of the controller room number labelled “# 6/12” is in place. Remove this  
shunt if this room is to start in the louder position #12.  
white/orange 3  
green 2  
white/green 1  
To restore the boot up defaults, replace the appropriate room shunts.  
3
6
 
VC224pm and VC226pm typical wiring diagram  
Power supply.  
Connect to the  
switched oulet on  
the receiver or  
amplifier if  
To have a room or zone  
start with the music  
onwhentheVC226pm  
powersup, removethe  
shuntlabelled  
possible  
S/MUTE. Otherwise  
the keypad has to be  
pushedorremote  
One or two VC201  
keypadsorone  
VC201ikeypadcan  
control each rooms  
stereospeakers.  
Connect the one or  
two VC201 or one  
VC201i keypad to  
the VC226pm  
touched to turn on this  
roomonly.  
VC226pm Cabinet  
Whenthesounddoes  
comeon(whetheror  
not S/MUTE is  
selected)thesound  
always comes on in  
position #6 (of 17  
total). To make the  
music start in this  
room only at position  
#12, removetheshunt  
labelled#6/12.  
Labeled wrong on version 1.3  
cabinet's correct  
RJ45 8 conductor  
connector using a  
home run of cat 5  
wire. Be sure to  
use a good quality  
RJ45 8/8 crimper.  
IR OUT  
12VDC  
INPUT ROOM1 ROOM2  
ROOM3 ROOM4  
ROOM5 ROOM6  
Homerun  
fourconductor  
speaker wire  
Homerun  
12vdc 500mA  
Connectthe  
power amplifier's  
speakeroutputs  
totheVC226pm  
jacklabelled  
cat 5 wire  
"INPUT"  
Make sure proper  
wire polarity is  
observed.  
120 WATT  
MAXIMUM  
STEREO  
VC201Keypad  
4-16 OHMS  
IR55  
VC201Keypad  
Speakers  
ROOM #1  
Infraredconnection  
module to emitters  
AMPLIFIER  
ROOM #6  
 

Indesit Oven FDE20 User Manual
Jenn Air Refrigerator JUC2450ARB User Manual
JL Audio Car Speaker VR525 CXi User Manual
JVC Microphone CU V10U User Manual
JVC Stereo Receiver RX 80PGD User Manual
Kenmore Dehumidifier 58053509 User Manual
Kenmore Refrigerator 241815202 User Manual
Kenmore Washer 1102982 User Manual
Kodak Projector DP2000 User Manual
Kompernass Label Maker KH3229 09 06 V2 User Manual